FM Transmitter Measurement Report
Created: 2025-03-17 21-11-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.60 MHz 3/5, 31 dBuV COURTOIS
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 14 kHz 1179 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
3,9 dBr 4,46 dBr 4,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"COURTOIS" F228 0 (No PTY) 0 0 1 1 21:09, 17.03.2025
RT
-
AF EON
95.6, 101.1, 104.5 MHz -
FM Scope Station: 95.60 MHz, signal: 3/5 (31 dBuV) Max at: 14 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2025/03/17 21:10:23 Total samples: 1179 Equivalent time: 0:00:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40
FM Scope MAX: 4,9 dBr MIN: 3,9 dBr AVE: 4,46 dBr % above 10,2 dBr: 0,0 Last value: 3,9 dBr (2025/03/17 21:10:22) Station: 95.60 MHz, signal: 4/5 (31 dBuV) 21:03 21:04 21:05 21:06 21:07 21:08 21:09 21:10 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality